Abstract
Full text PDF
Aim. A successful implant therapy is based on an accurate assessment of the anatomy of the jaws. The aim of our study was to evaluate the reliability of magnetic resonance imaging (MR) compared with computed tomography (CT) for dental implant planning in respect to bone measurements and to observe and analyze the differences.
Method. We have studied 30 cases in which scans were performed with CT and MR. The images provided by the MR and CT examinations were delivered to three specialists in oral and maxillofacial radiology to measure the bone height at the specific sites.The measurements obtained by the specialists in MR and CT images were compared using the ANOVA test with a 0.05 significance level.
Result. In all 30 cases examined, MR images appeared perfectly comparable to CT images. The differences between the measurements from the MR and CT exams varied from 0.04 to 1.1 mm. There were no statistically significant differences (P=0.9).
Conclusion. The MR, when compared with CT, shown to be reliable in respect to bone measurements for dental implant planning. However, further studies are necessary to determine the technical advantages of Resonance at lower fields, compared with those of CT and MR with medium or high magnetic field.

Vol. 9 (No. 2) 2018 May-August

  1. Torque expression of a customized lingual appliance according to different elastomeric ligatures over time: an in vitro study
    Migliorati M., Poggio D., Drago S., Lagazzo A., Stradi R., Barberis F., Silvestrini-Biavati A.
    doi: 10.11138/ads/2018.9.2.059
  2. Photodynamic therapy on a biofilm monospecie of candida albicans: an in vitro study
    Palaia G., Tenore G., Del Vecchio A., Pergolini D., Tramutola L., Berlutti F., Romeo U.
    doi: 10.11138/ads/2018.9.2.065
  3. The effect of a brushing motion inside a sequence: an in vivo study
    Gambarini G., Seracchiani M., Piasecki L., Galli M., Valenti Obino F., Di Nardo D., Testarelli L.
    doi: 10.11138/ads/2018.9.2.072
  4. The effect of vitamin C on urinary level of an oxidative stress biomarker during at-home tooth bleaching process: a randomized double blinded clinical trial
    Akbari M., Nemati-Karimooy A., Hashemy S.I., Mohammadipour H.S.
    doi: 10.11138/ads/2018.9.2.077
  5. Computer-guided bone lid osteotomy with piezosurgery
    Sivolella S., Brunello G., Fincato A., De Stavola L.
    doi: 10.11138/ads/2018.9.2.084
  6. Resonance frequency evaluation on immediate loading implants with angled abutments: case series
    Notaro V., Rapone B., Cagnetta G., Sportelli P., Nardi G.M., Corsalini M.
    doi: 10.11138/ads/2018.9.2.091
Last Viewed articles: la lista degli ultimi x visitati.
  1. A comparative study of Magnetic Resonance (MR) and Computed Tomography (CT) in the pre-implant evaluation
    Pompa V., Galasso S., Cassetta M., Pompa G., De Angelis F., Di Carlo S.
credits